[Q25-Q46] 100% Guaranteed Results DCDC-003.1 Unlimited 160 Questions [2026]

Share

100% Guaranteed Results DCDC-003.1 Unlimited 160 Questions [2026]

DCDC-003.1 Dumps PDF - Want To Pass DCDC-003.1 Fast

NEW QUESTION # 25
What is the preferred location of the power distribution unit?

  • A. a service gallery outside the computer room, if the A H J and feeder distances allow
  • B. in an unused area of another floor
  • C. inside a ventilation duct
  • D. under each server rack

Answer: A


NEW QUESTION # 26
What are the speed and distance limitations of ESCON?

  • A. 1 Gbps @ up to 100m
  • B. 100 Mbps @ up to 20km
  • C. 17 MB/s @ up to 60km
  • D. 10 Gbps @ up to 40km

Answer: C


NEW QUESTION # 27
What is the appropriate fire rating requirements for an electrical room?

  • A. 1/2 hour
  • B. 3 hours
  • C. 2 hours
  • D. 1 hour

Answer: D


NEW QUESTION # 28
What is the Typical Voltage Of A Utility Sub-Station?

  • A. Low voltage at 480 or less volts
  • B. The United States uses only Direct Currents DC
  • C. Medium to Low-voltage range between 270 to13800 volts
  • D. High voltage at a stunningly high rate

Answer: C


NEW QUESTION # 29
What is the recommended amount of fuel supply needing to be available to a class F3 data center?

  • A. 48 hours
  • B. 24 hours
  • C. 72 hours
  • D. 96 hours

Answer: C


NEW QUESTION # 30
where should printers be located

  • A. in a dedicated print room with dedicated air handling system
  • B. near equipment that has active air flow to cool them down
  • C. beside high traffic areas
  • D. placed outdoor, away from building facilities

Answer: A


NEW QUESTION # 31
Which areas should generate a history of all access attempts and monitored by CCTV Security System?

  • A. Storage Areas
  • B. Loading Docks
  • C. Computer rooms, Loading docks, storage areas, Staging areas and Vendor Storage
  • D. Only computer rooms
  • E. Any concealed places

Answer: C


NEW QUESTION # 32
What is the second preference regarding utility service?

  • A. Two balanced feeds with different voltages derived from a single distribution station
  • B. At least One Circuit from two Separate Substations and Different Voltage Levels
  • C. One balanced feeder coordinated with upstream backup feed
  • D. At least four circuits each from different distribution stations but fed via common feeders

Answer: B


NEW QUESTION # 33
What room should have its own dedicated air handling system apart from the computer room?

  • A. Printer Room
  • B. Break Room
  • C. Storage Room
  • D. Telecommunications Room
  • E. Electrical Room

Answer: A


NEW QUESTION # 34
What is the recommended clearance space required for hot and cold aisles in a data center?

  • A. 3-4 feet
  • B. 7-8 feet
  • C. 1-2 feet
  • D. 5-6 feet

Answer: A


NEW QUESTION # 35
What is the minimum distance recommended between a data center's backup generator and the main data center building?

  • A. 40 feet
  • B. 30 feet
  • C. 10 feet
  • D. 20 feet

Answer: B


NEW QUESTION # 36
What is the acceptable rate of temperature change per hour in a data center according to TIA-942?

  • A. 12 degrees
  • B. 7 degrees
  • C. 9 degrees
  • D. 15 degrees
  • E. 5 degrees

Answer: C


NEW QUESTION # 37
What is the ASHRAE TC 9.9 recommended range for humidity levels in a data center?

  • A. 40-60%
  • B. 20-50%
  • C. 60-80%
  • D. 80-100%

Answer: A


NEW QUESTION # 38
What is the minimum height of a ceiling in a data center or telecommunications room?

  • A. eight feet from finished floor to any obstruction, sprinklers, lighting
  • B. twelve feet from finished floot to pay constructionjssgspritesari sek
  • C. Five feet from finished floor to any obstruction, sprinklers, lighting
  • D. ten feet from finished foroor to asany oos obstruction, sprinklers, lighting(correct)

Answer: D


NEW QUESTION # 39
What is the flame index spread rating required for all materials hosted in a containment system?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B


NEW QUESTION # 40
what are the dimensions of circulation pathways?

  • A. None
  • B. All
  • C. 4 feet wide and have clear overhead of 8 feet
  • D. 5 feet width with a height of 7feet.
  • E. 6feet width, width depends on the layout functionality.

Answer: C

Explanation:
Explanation:


NEW QUESTION # 41
What is the minimum aisle width?

  • A. The width shouldn't exceed more than half room length
  • B. Twice server cabinet depth
  • C. 3 feet
  • D. Arm span distance between technicians

Answer: C


NEW QUESTION # 42
What is the recommended level of redundancy for a critical power system in a Tier III data center?

  • A. N
  • B. 2N
  • C. 2N+1
  • D. 3N
  • E. N+1

Answer: E


NEW QUESTION # 43
What Enhanced Fujita Scale level is commonly used in wind loading calculations?

  • A. EF3,158-206mph
  • B. EF4,207-260 mph
  • C. EF1,73-112 mph
  • D. EF2,113-157mph

Answer: B


NEW QUESTION # 44
What is the most common energy storage solution and what are the two types?

  • A. Lithium-ion battery, sealed and unsealed
  • B. Lead-acid battery, vented and valve regulated
    Nickel-cadmium battery, vented and valve regulated
  • C. Flywheel, vertical and horizontal
  • D. Supercapacitor, cylindrical and prismatic

Answer: B


NEW QUESTION # 45
Where should all Storage and Unpacking activities occur?

  • A. Inside Computer Room
  • B. Near the Main Entrance of Data Center
  • C. Outside the Building, at a secure location.
  • D. Outside Computer room, either in Storage Rooms or Staging Areas located adjacent to Computer Room with Dedicated air Handling
  • E. None of these

Answer: D


NEW QUESTION # 46
......

Updated Verified DCDC-003.1 Q&As - Pass Guarantee: https://prep4sure.examtorrent.com/DCDC-003.1-exam-papers.html