NEW QUESTION # 243
NETCOL5000-C temperature and humidity sensor dial-code setting error may cause:
- A. The return air temperature or fan speed fluctuates greatly
- B. The temperature and humidity sensor cannot detect the temperature and humidity
- C. The drainage capacity of the equipment is significantly reduced
- D. Water leakage at the bottom of the device
Answer: B
NEW QUESTION # 244
FusionModule2000 can implement battery enlisting or not enlisting according to different layouts.
- A. False
- B. True
Answer: B
NEW QUESTION # 245
A single row of FusionModule 2000 supports a maximum of 48 cabinets.
- A. True
- B. False
Answer: B
NEW QUESTION # 246
How many KG is the static load of the FusionModule2000 cabinet?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION # 247
How many groups of battery strings that a single UPS5000 can support? (Multiple choice)
- A. 1 group
- B. 4 groups
- C. 3 groups
- D. 2 groups
Answer: A,B,C,D
NEW QUESTION # 248
UPS5000-A has built-in SNMP and ModBus card, which reduces the management investment cost of customers.
- A. False
- B. True
Answer: B
NEW QUESTION # 249
The UPS5000-E has strong load adaptability, and the capacitive/inductive load is super strong/lag () without derating.
- A. 0.7
- B. 0.5
- C. 0.4
- D. 0.6
Answer: B
NEW QUESTION # 250
What methods are supported by the FusionModule800 UPS configuration?
- A. N/2N
- B. N/N+1/2N
- C. N/N+1
Answer: B
NEW QUESTION # 251
If the UPS5000-E is overloaded in normal mode, it transfers to bypass mode immediately. The bypass supplies power to loads to protect the UPS.
- A. True
- B. False
Answer: B
NEW QUESTION # 252
FusionModule2000 IT cabinet seismic rating?
- A. 0
- B. 1
- C. 2
Answer: A
NEW QUESTION # 253
ECC800 supports two AC inputs.
- A. False
- B. True
Answer: B
NEW QUESTION # 254
What is the channel width of Huawei FusionModule2000?
- A. 1200mm
- B. 1300mm
- C. 1000mm
- D. 1100mm
Answer: A
NEW QUESTION # 255
The function of the back-feed protection card is that when the energy back-feed occurs in the main circuit or the bypass, the back-feed protection card sends a drive alarm signal, and the drive trip switch (configured by the customer) is disconnected, which plays the role of back-feed protection.
- A. False
- B. True
Answer: B
NEW QUESTION # 256
What is the incoming line mode supported by UPS5000-A-400/500K?
- A. lower incoming
- B. Compatible with upper and lower incoming lines
- C. upper incoming
Answer: B
NEW QUESTION # 257
What is the range of the number of battery cabinets in the FusionModule800 module?
- A. 0-3
- B. 0-4
- C. 0-2
- D. 0-1
Answer: C
NEW QUESTION # 258
The UPS5000-E battery adopts the design of no center line, which is convenient to replace the old battery when the tower machine is replaced.
- A. True
- B. False
Answer: B
NEW QUESTION # 259
When the single cell voltage in the battery pack reaches (______), it means that the battery pack is already in a risky state. (Fill in the blank)
Answer:
Explanation:
1.67V
NEW QUESTION # 260
......
Download the Latest H12-425_V2.0-ENU Dump - 2024 H12-425_V2.0-ENU Exam Question Bank: https://prep4sure.examtorrent.com/H12-425_V2.0-ENU-exam-papers.html